FR90HA
is applicable to power cable, power supply cord, signal cable and communication cable with excellent flame retardancy and extrudability. It passes VW-1 (Single Vertical Flame Test), and complies with IEC60332-3 Level A, B and C (flame test on bunched wires/cables) with different cable construction. |
|
|
|
|
Item |
Unit |
Typical Value |
Test Method |
Density |
g/cm3 |
1.21 |
ISO 1183 |
Melt Flow Index |
g/10min |
0.60 |
ISO 1133 |
HCL generation |
% |
ND |
IEC 60754-1 |
LOI |
% |
32 |
ISO 4589 |
Conductivity |
μS/mm |
7.5 |
IEC 60754-2 |
20 ℃ Volume Resistivity |
Ω .m |
1.18 x 10 11 |
IEC 60093 |
pH Value |
|
8 |
IEC 60754-2 |
Smoke Density |
Non-Flaming mode |
|
71 |
ASTM E662 |
Flaming mode |
|
180 |
ASTM E662 |
Tensile Strength |
MPa |
12 |
IEC 60811 |
Elongation |
% |
400 |
IEC 60811 |
Heat Aging Method |
°C × h |
110 °C ×168h |
IEC 60811 |
Change of Tensile Strength |
% |
9 |
IEC 60811 |
Change of Elongation |
% |
15 |
IEC 60811 |
Heat Deformation |
% |
5 |
IEC 60811 |
Toxicity index |
|
3.1 |
NES 713 |
Cold Brittleness (-25°C) |
|
Pass |
IEC 60811 |
|
1) Processing Temperature |
|
|
The recommended temperature range is 120°C-170°C |
|
|
|
|
Barrel 1 |
Barrel 2 |
Barrel 3 |
Barrel 4 |
Barrel 5 |
Barrel 6 |
120°C |
150°C |
160°C |
165°C |
170°C |
170°C |
|
|
|
|
2) Extrusion Equipment |
|
|
It can be processed in ordinary PVC processing machine, standard extruders with gradually changing screw having L/D
≧ 25. |
|
|
|
|
|
|